ZigaForm version 7.6.9

R129,030.00

SKU: RO2000LPH Category:
Delivery and return
Delivery and return

Next day delivery in store

Buy before 6pm to receive your order next day.
FREE

Next day delivery

Orders before 6pm from Monday to Saturday (or before 1pm on Sunday) will be delivered Next working day (except Northern Ireland and Highlands). Orders placed after 6pm (after 1pm on Sunday) or for Northern Ireland and Highlands will be delivered in 2 working days.
29 USD

Drop Point

In 2-3 working days. Pick up your parcel in one of the many diferent collection points available and during a wide range of hours.
39 USD

Same day delivery in London:

Place your order before 13:00 to get it today!. If you order later on, you’ll receive it the next day and if you order on Sunday, you’ll receive it the next working day.
59 USD
Shipping Information
Shipping Information

SHIPPING

Complimentary ground shipping within 1 to 7 business days In-store collection available within 1 to 7 business days Next-day and Express delivery options also available Purchases are delivered in an orange box tied with a Bolduc ribbon, with the exception of certain items See the delivery FAQs for details on shipping methods, costs and delivery times
Composition and care
Composition and care

Characteristics of wood :

  • Hard, compact , fiberous and porous
  • Good wood gives a rich, warm and beautiful surface.

Wood is used for the construction of:

  • Floor, Furniture, Walls
  • Incidental furnishing (lampshades, picture frames)
  • Kitchen & restaurant ware

Description

2000 LPH Reverse Osmosis System – Industrial Water Purification

The 2000 LPH reverse osmosis system is an industrial water purifier designed to remove dissolved salts, minerals, and other impurities from feed water. It produces up to 2 T/H (2000 litres per hour) of clean water, making it suitable for industrial plants, bottling facilities, commercial operations, and laboratories.

Because this is a standalone RO unit, it does not include pretreatment equipment. Therefore, sediment filters, carbon filters, or antiscalant dosing should be installed upstream to protect the membranes. As a result, the system delivers consistent, low-TDS water for industrial use.

How It Works

Feed water first enters the system, and the high-pressure pump drives it through semi-permeable RO membranes. Consequently, salts and impurities are rejected to the wastewater side, while purified water passes through to the product line.

Meanwhile, flow meters, pressure gauges, and panel controls allow operators to monitor the system in real time. Therefore, the membranes remain protected, and the system runs efficiently even during continuous operation.

Key Features

  • High output of 2000 LPH (2 T/H)
  • Industrial-grade RO membranes for strong salt and impurity removal
  • Durable FRP and stainless steel construction
  • Built-in flow meters and pressure gauges for easy monitoring
  • Efficient energy use with 5 kW system power consumption
  • Easy operation and maintenance
  • Ideal for continuous industrial or commercial use

System Components

The 2000 LPH RO system includes:

  1. High-pressure pump: CDM4-12, 2.2 kW, 380 V / 50 Hz, flange type (Q = 4 m³/h, H = 95 m, NPSH = 2, N = 2900 rpm)
  2. FRP membrane housing: 4040 × 8 pcs
  3. RO membranes: 4040 × 8 pcs
  4. 20″ jumbo blue filter housing: 2 pcs
  5. Brass solenoid valves: inlet 1.2″, flush 1″
  6. Brass globe valves: DN15 × 2 pcs, DN20 × 1 pc
  7. Coated electric box × 1
  8. Pressure switches: -0.5~3 bars × 1, 5~30 bars × 1
  9. UPVC pipes PN16 × 1 lot
  10. Flow meters: wastewater 1–10 GPM × 1, product 2–20 GPM × 1
  11. Pressure gauges: panel type 1 MPa × 1, 2.5 MPa × 2

Technical Parameters

Parameter Specification
Model – SKU RO2000LPH
Capacity 2 T/H (2000 LPH)
Power (kW) 2.2 kW
Inlet Pressure 3 bars
Running Pressure 8–10 bars
Voltage 380 V / 50 Hz, 3P
Membrane Recovery Rate 15%
Desalination Rate 95–98%
System Recovery 50%
Max Feed TDS 2000 ppm
Max Input Temp 30 °C
Inlet Pipe Size 1.2″
Product Water Pipe Size 1″
Waste Water Pipe Size 1″
System Power Consumption 5 kW

Operation & Performance

This system operates under high pressure, which forces water molecules through the RO membranes while rejecting salts and impurities. Therefore, the system consistently produces low-TDS water.

In addition, the built-in monitoring instruments allow operators to track flow and pressure. As a result, membrane performance is maintained, and the system runs efficiently over long periods.

Applications

The 2000 LPH reverse osmosis system is ideal for:

  • Industrial water treatment plants
  • Commercial and factory water supply
  • Beverage and bottling facilities
  • Food processing operations
  • Laboratories and pharmaceutical water supply

Because of its high output and reliability, it performs well in continuous-use industrial environments.

Installation & Maintenance Notes

  • Conduct a water analysis before installation to determine pretreatment needs.
  • Install sediment, carbon filters, and antiscalant dosing upstream to protect membranes.
  • Qualified technicians should handle installation and commissioning.
  • Regularly monitor flow, pressure, and TDS to maintain performance.