ZigaForm version 7.6.7

R2,499.99

Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.

Out of stock

SKU: LP11-4040 Category:
Delivery and return
Delivery and return

Next day delivery in store

Buy before 6pm to receive your order next day.
FREE

Next day delivery

Orders before 6pm from Monday to Saturday (or before 1pm on Sunday) will be delivered Next working day (except Northern Ireland and Highlands). Orders placed after 6pm (after 1pm on Sunday) or for Northern Ireland and Highlands will be delivered in 2 working days.
29 USD

Drop Point

In 2-3 working days. Pick up your parcel in one of the many diferent collection points available and during a wide range of hours.
39 USD

Same day delivery in London:

Place your order before 13:00 to get it today!. If you order later on, you’ll receive it the next day and if you order on Sunday, you’ll receive it the next working day.
59 USD
Shipping Information
Shipping Information

SHIPPING

Complimentary ground shipping within 1 to 7 business days In-store collection available within 1 to 7 business days Next-day and Express delivery options also available Purchases are delivered in an orange box tied with a Bolduc ribbon, with the exception of certain items See the delivery FAQs for details on shipping methods, costs and delivery times
Composition and care
Composition and care

Characteristics of wood :

  • Hard, compact , fiberous and porous
  • Good wood gives a rich, warm and beautiful surface.

Wood is used for the construction of:

  • Floor, Furniture, Walls
  • Incidental furnishing (lampshades, picture frames)
  • Kitchen & restaurant ware

Description

Vontron ULP11‑4040 RO Membrane – Ultra‑Low‑Pressure 4″×40″

The Vontron ULP11‑4040 RO Membrane is an ultra-low-pressure (ULP) reverse osmosis element designed for municipal water, surface water, and low‑salinity applications. This high-performance RO membrane reduces energy costs while maintaining excellent water quality. With a standard 4″×40″ size, it fits most RO systems for domestic and light industrial use.

Key Features of Vontron ULP11‑4040 RO Membrane

  • Ultra‑low pressure operation minimizes pump energy requirements.
  • Typical permeate output of 2,700 GPD with 97.5–99% salt rejection.
  • Standard 4″×40″ size ensures easy integration.
  • Suitable for feedwater TDS up to 2,000 ppm.
  • Robust operating limits: max 600 psi pressure, 45 °C temperature.

Technical Specifications

Parameter Value
Model ULP11‑4040
Active Membrane Area ~90 ft² (≈8.4 m²)
Typical Permeate Flow ~2,700 GPD (~10.2 m³/day) under test conditions
Stable Rejection Rate 98.0% (typical)
Minimum Rejection Rate 97.5%
Testing Conditions Test Pressure: 150 psi (1.03 MPa)
Test Solution: 1,500 ppm NaCl, 25 °C, pH 7.5
Recovery Rate: 15% (single element)
Max Feed Operating Pressure 600 psi (~4.14 MPa)
Max Feed Flow ~16 gpm (~3.6 m³/hr) for 4040 size
Max Feed Temperature 45 °C
Max Feed SDI ≤ 5
Residual Chlorine in Feed < 0.1 ppm
pH Range (Continuous Operation) 3 to 10
pH Range (Cleaning) 2 to 12
Max Pressure Drop (single element) 15 psi (~0.1 MPa)
Physical Dimensions Length ≈ 1016 mm (40″)
Outer Diameter ≈ 99.7 mm (3.9″)

Why Choose the Vontron ULP11‑4040 RO Membrane?

Because it blends compact size with high capacity and efficiency, this membrane is a smart upgrade for systems treating municipal or low‑brackish water where energy cost and pump size matter. Its ultra-low-pressure design cuts operating cost and simplifies system design. Additionally, its proven brand and performance make it reliable for commercial installations.

Benefits of Using Vontron ULP11‑4040

This RO membrane ensures reliable, high‑quality water for domestic, commercial, and light industrial systems. It reduces operational costs, fits standard housings, and guarantees long-term performance. Perfect for retrofits and new installations alike.

Installation & Maintenance Tips

  • Ensure pre‑treatment: feed silt density index (SDI) ≤ 5; free chlorine in feed < 0.1 ppm.
  • On initial startup, flush new element: 15‑25 minutes at low pressure, then 60‑90 minutes at design pressure. Discard the first hour permeate.
  • Monitor permeate flow and rejection: declining performance may indicate fouling, scaling, or damage.
  • Clean according to manufacturer guidelines, observe pH limits (cleaning 2‑12).
  • Store spares wet or in a protective solution (1% sodium bisulfite) if the system is idle.