ZigaForm version 7.6.7

R182.16

Independently developed by VONTRON, the RO element ULP1812-50 is designed for the treatment of low-salinity water resources such as tap water, well water, etc. Working under extra-low pressure, it is applicable to water purifying devices in residence, hospital, and laboratory.

SKU: ULP1812-50 Category:
Delivery and return
Delivery and return

Next day delivery in store

Buy before 6pm to receive your order next day.
FREE

Next day delivery

Orders before 6pm from Monday to Saturday (or before 1pm on Sunday) will be delivered Next working day (except Northern Ireland and Highlands). Orders placed after 6pm (after 1pm on Sunday) or for Northern Ireland and Highlands will be delivered in 2 working days.
29 USD

Drop Point

In 2-3 working days. Pick up your parcel in one of the many diferent collection points available and during a wide range of hours.
39 USD

Same day delivery in London:

Place your order before 13:00 to get it today!. If you order later on, you’ll receive it the next day and if you order on Sunday, you’ll receive it the next working day.
59 USD
Shipping Information
Shipping Information

SHIPPING

Complimentary ground shipping within 1 to 7 business days In-store collection available within 1 to 7 business days Next-day and Express delivery options also available Purchases are delivered in an orange box tied with a Bolduc ribbon, with the exception of certain items See the delivery FAQs for details on shipping methods, costs and delivery times
Composition and care
Composition and care

Characteristics of wood :

  • Hard, compact , fiberous and porous
  • Good wood gives a rich, warm and beautiful surface.

Wood is used for the construction of:

  • Floor, Furniture, Walls
  • Incidental furnishing (lampshades, picture frames)
  • Kitchen & restaurant ware

Description

Vontron 1812 50 GPD RO Membrane – Compact 1.8″×12″

The Vontron 1812 50 GPD RO Membrane is a compact, high-quality reverse osmosis element sized 1.8″ diameter × 12″ length (designated “1812”), specifically engineered for residential or small point-of-use systems. It delivers approximately 50 gallons per day (GPD) under standard test conditions, with a stable salt rejection of around 97%. Designed for low-salinity sources such as municipal tap water or shallow wells, this membrane is ideal when space is limited but water purity remains essential.

Key Features

  • Compact 1.8″ × 12″ (1812 format) — perfect for tight installations.
  • Rated output: ~50 GPD (~190 L/day) under test conditions.
  • Salt rejection: ~97% stable; minimum ~96% under standard conditions.
  • Low-pressure design enabling integration into cost-sensitive or smaller systems.
  • Suitable for residential uses: under-sink, countertop, small lab or office water purification.

Technical Specifications

Parameter Value
Model ULP1812-50
Format 1.8″ diameter × 12″ length
Rated Permeate Flow ~50 GPD (~190 L/day)
Stable Salt Rejection ≈ 97%
Minimum Salt Rejection ≈ 96%
Test Conditions 60 psi (~0.41 MPa), 25 °C, 250–500 ppm NaCl, pH ~6.5–7.5
Maximum Feed Pressure ~200 psi (~2.0 MPa)
Maximum Feed Temperature 45 °C
Maximum SDI (Silt Density Index) ≤ 5
Free Chlorine in Feed < 0.1 ppm
Feed pH Range (Operation) 3 – 10
Feed pH Range (Cleaning) 2 – 11
Maximum Pressure Drop Single Membrane ~10 psi (~0.07 MPa)

Why Choose the Vontron 1812 50 GPD RO Membrane?

Opting for the Vontron 1812 50 GPD RO Membrane means choosing a space-saving, high-efficiency RO element that delivers meaningful purification in a compact format. Because it’s designed for low-salinity feed water and works at modest pressure, it’s ideal for residential installations where footprint and cost matter. The strong rejection rate ensures water quality without needing oversized systems.

Installation & Maintenance Tips

  1. Pre-treat feed water: ensure SDI ≤ 5 and free chlorine < 0.1 ppm to protect membrane life.
  2. On first use, flush the new membrane per manufacturer guidelines; discard early permeate.
  3. Monitor the permeate flow and salt rejection; if performance drops significantly, check for fouling, scaling or damage.
  4. Maintain temperature, pressure, and pH within specified limits to prolong membrane lifespan.
  5. If the membrane will be unused for some time, store it wet or in an approved preservative solution.